**KAWAKI Measuring Instrument Co., Ltd. – Company & Product Overview**
**KAWAKI Measuring Instrument Co., Ltd.** is a Japanese manufacturer specialized in the development and production of flow rate measurement instruments. The company is known for a diverse range of flow meters—including orifice, shuttle-type, and area flow meters—that cater to various industrial fluid monitoring applications.
---
### **Company Profile**
* **Company Name:** KAWAKI Measuring Instrument Co., Ltd.
* **Founded:** April 1948
* **Headquarters:** 5‑6‑28 Kisaki, Akashi City, Hyogo Prefecture, Japan
* **Core Competency:** Design and manufacture of reliable, precise flow rate measurement gauges, tailored for industrial and process-control systems
---
### **Product Range & Applications**
KAWAKI specializes in several precision flow meter designs:
* **Orifice Flow Meters**
* **Area Flow Meters**
* **Shuttle-type Flow Meters**
* **Other Related Instruments**
Products are utilized across industries, including:
* **Steam Systems**
* **Water Treatment**
* **Gas and Chemical Processing**
* **Industrial Automation**
These meters are crafted for robustness and accuracy, with specific naming such as “KY‑MA” or “SF‑MAA” and materials ranging from cast iron to stainless steel, designed to suit a variety of piping standards and environmental requirements (e.g., JIS, ANSI, high-pressure ratings).
---
### **Technical Strengths & Industry Impact**
1. **Precision Engineering**
Designed for accurate detection and measurement of flow, providing stable readings in industrial processes.
2. **Material & Compatibility**
Available in cast iron or stainless steel, suitable for corrosive and high-pressure environments.
3. **Versatile Mounting & Configurations**
Supports wafer, flange, and threaded connections in various standard sizes (15A to 350A, 1/2″ to 14″), facilitating integration into existing piping systems.
4. **Durability & Outdoor Use**
Rated for up to 2.0 MPa working pressure and fluid temperatures from –10 °C to 70 °C, with an IP65 rating allowing for safe outdoor deployment.
5. **Global Reach**
Widely deployed in markets such as Southeast Asia—flow meters exported for use in steam systems and process lines.
---
### **Summary Table**
| Product Type | Characteristics | Typical Use Cases |
| ------------------- | ------------------------------------------------- | ------------------------------------- |
| Orifice Flow Meter | Durable, cost-effective, large diameters possible | Steam lines, industrial water systems |
| Area/Shuttle Meters | Compact flow sensing with high accuracy | Gas, chemical, and fluid processes |
| Material Options | Cast iron and SS options | Corrosive or clean environments |
| Mounting Types | Wafer, flange, screw connections | Pipelines across multiple standards |
| Operating Specs | Up to 2.0 MPa pressure, –10 to 70 °C, IP65 | Outdoor and industrial installations |
---
## **Conclusion**
**KAWAKI Measuring Instrument Co., Ltd.** is a trusted Japanese provider of high-precision flow rate instruments, offering diverse models like orifice, area, and shuttle-type flow meters. Built for accuracy, reliability, and adaptability to multiple industrial fluid systems, their products support customers with robust performance in demanding environments. If you'd like a Thai translation next or wish to proceed with another company profile, I’m here to assist!
Here’s the cleaned and translated version in **English** (with all links removed as you requested):
---
## Product Series and Models
### 1. MFI Type Multi Flow Sight
Belongs to the "Multi Flow Sight" product series.
---
### 2. Area Flow Meter / Flow Switch
This series includes the following models:
* SR type flow meter
* KNR type flow meter
* NF type flow switch
* INF type flow meter / flow switch
---
### 3. NF Type Flow Switch with Indicator (Compact Area Flow Meter for Liquid/Gas)
A specific model is **INF-M**, which is a compact NF type area flow meter designed for horizontal pipelines, applicable for both liquids and gases.
---
### 4. Other Product Categories (from the Product Guide and Sitemap)
* Flow Meter / Flow Switch (general)
* Flow Sight
* Orifice Flow Meter
* Other specific models and pages such as fmfs05, fs03, fs01, etc., which belong to the above categories as sub-models or variants.
---
## Summary Table
| Product Series | Specific Models / Types |
| ------------------------ | -------------------------------------------------------- |
| MFI Multi Flow Sight | MFI type multi flow sight |
| Area Flow Products | SR / KNR / NF / INF type flow meter / flow switch |
| Compact Model in Series | INF-M (Compact NF Area Flow Meter) |
| Other Product Categories | Flow Meter / Flow Switch; Flow Sight; Orifice Flow Meter |
**บริษัท คาวากิ เมเชอริ่ง อินสตรูเมนท์ จำกัด** เป็นผู้ผลิตจากประเทศญี่ปุ่นที่เชี่ยวชาญด้านการพัฒนาและการผลิตเครื่องมือวัดอัตราการไหล บริษัทนำเสนอเครื่องวัดการไหลหลายประเภท เช่น เครื่องวัดอัตราการไหลแบบออริฟิซ, แบบลูกสูบ และแบบพื้นที่ ซึ่งสามารถนำไปใช้ในระบบตรวจสอบของไหลในอุตสาหกรรมที่หลากหลาย
---
### ข้อมูลบริษัท
* **ชื่อบริษัท:** บริษัท คาวากิ เมเชอริ่ง อินสตรูเมนท์ จำกัด
* **ก่อตั้งเมื่อ:** เดือนเมษายน พ.ศ. 2491
* **สำนักงานใหญ่:** เลขที่ 5‑6‑28 คิซากิ เมืองอาคาชิ จังหวัดเฮียวโงะ ประเทศญี่ปุ่น
* **ความเชี่ยวชาญหลัก:** การออกแบบและการผลิตเครื่องวัดอัตราการไหลที่มีความแม่นยำและเชื่อถือได้ สำหรับระบบควบคุมกระบวนการทางอุตสาหกรรม
---
### ผลิตภัณฑ์และการใช้งาน
คาวากิ เชี่ยวชาญด้านเครื่องวัดอัตราการไหลที่มีความแม่นยำหลากหลายรูปแบบ ได้แก่:
* **เครื่องวัดอัตราการไหลแบบออริฟิซ**
* **เครื่องวัดอัตราการไหลแบบพื้นที่ (Area Flow Meters)**
* **เครื่องวัดอัตราการไหลแบบลูกสูบ (Shuttle-type)**
* **อุปกรณ์ที่เกี่ยวข้องอื่น ๆ**
ผลิตภัณฑ์ถูกนำไปใช้อย่างกว้างขวางในอุตสาหกรรมต่าง ๆ เช่น:
* ระบบไอน้ำ
* ระบบบำบัดน้ำ
* การประมวลผลก๊าซและเคมีภัณฑ์
* ระบบอัตโนมัติในโรงงาน
เครื่องวัดแต่ละรุ่นถูกออกแบบให้มีความทนทานและแม่นยำ โดยมีชื่อรุ่นที่พบได้ทั่วไป เช่น “KY‑MA” หรือ “SF‑MAA” มีให้เลือกทั้งวัสดุเหล็กหล่อและสเตนเลส เพื่อรองรับการใช้งานในสภาพแวดล้อมที่หลากหลาย ทั้งมาตรฐาน JIS และ ANSI รวมถึงความดันสูง
---
### จุดแข็งทางเทคนิคและผลกระทบในอุตสาหกรรม
1. **วิศวกรรมที่แม่นยำ**
ออกแบบเพื่อการตรวจจับและวัดอัตราการไหลอย่างแม่นยำ ให้ค่าที่เสถียรในกระบวนการอุตสาหกรรม
2. **วัสดุและความเข้ากันได้**
มีให้เลือกทั้งเหล็กหล่อและสเตนเลส เหมาะสำหรับสภาพแวดล้อมที่มีการกัดกร่อนหรือความดันสูง
3. **การติดตั้งและการเชื่อมต่อที่หลากหลาย**
รองรับการติดตั้งแบบ Wafer, หน้าแปลน (Flange) และเกลียว (Thread) ในขนาดตั้งแต่ 15A ถึง 350A (1/2" ถึง 14")
4. **ความทนทานและใช้งานภายนอกได้**
ทนแรงดันได้สูงสุดถึง 2.0 MPa และอุณหภูมิของของไหลตั้งแต่ –10 °C ถึง 70 °C พร้อมค่าป้องกันระดับ IP65 สำหรับการใช้งานกลางแจ้ง
5. **ขยายตลาดทั่วโลก**
มีการส่งออกไปยังตลาดเอเชียตะวันออกเฉียงใต้และประเทศอื่น ๆ สำหรับใช้งานในระบบไอน้ำและสายการผลิต
---
### ตารางสรุปผลิตภัณฑ์
| ประเภทผลิตภัณฑ์ | คุณลักษณะเฉพาะ | ตัวอย่างการใช้งาน |
| -------------------- | --------------------------------------------- | ----------------------------------- |
| เครื่องวัดแบบออริฟิซ | ทนทาน ประหยัดต้นทุน รองรับขนาดท่อใหญ่ได้ | ระบบไอน้ำ ระบบน้ำอุตสาหกรรม |
| แบบพื้นที่/ลูกสูบ | ขนาดกะทัดรัด มีความแม่นยำสูง | ระบบก๊าซ เคมี และของเหลว |
| ตัวเลือกวัสดุ | เหล็กหล่อ และสเตนเลส | สภาพแวดล้อมที่กัดกร่อน/สะอาด |
| รูปแบบการติดตั้ง | Wafer, หน้าแปลน, เกลียว | ท่อในมาตรฐานต่าง ๆ |
| คุณสมบัติการทำงาน | ความดัน 2.0 MPa, อุณหภูมิ –10 ถึง 70 °C, IP65 | ใช้งานกลางแจ้งและในโรงงานอุตสาหกรรม |
---
## สรุป
**บริษัท คาวากิ เมเชอริ่ง อินสตรูเมนท์ จำกัด** เป็นผู้ผลิตจากประเทศญี่ปุ่นที่เชื่อถือได้ในด้านอุปกรณ์วัดอัตราการไหลที่มีความแม่นยำสูง ผลิตภัณฑ์ที่หลากหลายทั้งแบบออริฟิซ, แบบลูกสูบ และแบบพื้นที่ ถูกออกแบบมาเพื่อตอบโจทย์การควบคุมของไหลในระบบอุตสาหกรรมที่หลากหลาย ด้วยความทนทาน ความแม่นยำ และตัวเลือกการติดตั้งที่ยืดหยุ่น จึงเป็นพันธมิตรที่ไว้วางใจได้สำหรับระบบควบคุมในสายการผลิตอุตสาหกรรมทั่วโลก
KY type flow switch / flow meter
- Suitable for unclear liquid because the indication part is separated using a mechanical seal
- Flow direction is not restricted
- Contact position is variable
Type | KY-M type instantaneous flow rate indicator KY-MA type instantaneous flow rate indicator + with lower limit (upper limit) contact |
---|---|
Bore | 3/8B to 5B Flange type RC3/8 to RC1.1/2 Screw type |
Withstanding pressure | Standard product 1.0MPa |
Temperature | Standard product 80°C or less |
Accuracy | Each indication scale ±5% |
Capacity of contact | *15A: 125,250 or 480VAC,0.5A: 125VDC,0.25A: 250VDC |
Application |
|
Material of main unit | FC250,CAC406,SUS304 |
Material of main unit | C3604B,SUS304 |
Remark | *For places with frequent vibration, please use earthquake resistant SF type. *If the use pressure is 1.0MPa or more, use SF type for high pressure. *The range of minimum scale is 0 to 30L/min (water) and 0 to 20L/min (oil). |
SF type flow switch / flow meter
- Suitable for high-temperature and high-pressure liquid of unclear liquid (oil etc.)
- The contact of flow switch is the internal variable type, however, if you change the contact frequently, the external variable type is also manufactured.
- For use outdoors and at places with bad environment, totally waterproof type (IEC, IP67) is also manufactured.
Type | SF-M type instantaneous flow rate indicator SF-MA type instantaneous flow rate indicator + with lower limit (upper limit) contact SF-MAA type instantaneous flow rate indicator + with lower limit (upper limit) contact |
---|---|
Bore | 3/8B to 12B Flange type RC3/8 to RC1.1/2 Screw type |
Withstanding pressure | Standard product 1.0MPa Special order item 3.0MPa and above |
Temperature | Standard product 80°C or less Special order item 300°C or less |
Accuracy | Each indication scale ±3% |
Capacity of contact | For the micro switch used for the contact, three types shown below are separately used depending on bore and flow rate. *15A: 125,250VAC、0.5A: 125VDC、0.25A: 250VDC *5A: 125,250VAC、0.5A: 125VDC、0.25A: 250VDC *10A: 125,250VAC |
Material of main unit | FC250,CAC406,SS400,SUS304,SUS316,SUS316L etc. |
Material of main section | C3604B,SUS304,SUS316,SUS316L etc. |
Remark | *For places with frequent vibration, please use earthquake resistant type. |
FY type flow switch / flow meter
- This flow meter / flow switch is the down-sized SF type and the features are same as those of SF type and SA type.
- The external variable type is also manufactured.
Type | FY-M type instantaneous flow rate indicator FY-M type instantaneous flow rate indicator |
---|---|
Bore | 3/8B to 12B Flange type RC3/8 to RC1.1/2 Screw type |
Withstanding pressure | Standard product 1.0MPa |
Temperature | Standard product 80°C or less |
Accuracy | Each indication scale ±3% |
Capacity of contact | *5A: 125,250VAC,0.5A: 125VDC,0.25A: 250VDC |
Material of main unit | FC250,CAC406,SUS304 |
Material of main section | C3604B,SUS304 |
Remark | *For places with frequent vibration, please use earthquake resistant SF type. *If the use pressure is 1.0MPa or more, use SF type for high pressure. *For use outdoors and at places with bad environment, totally waterproof type (IEC, IP67) is also manufactured. |
SA type flow switch / flow meter
- Suitable for comparatively small flow rate (equivalent to water 0 to 15L/min) of high-temperature and high-pressure fluid of unclear liquid (oil, etc.)
Self-holding proximity switch | SA-M type instantaneous flow rate indicator SA-MA type instantaneous flow rate indicator + with lower limit (upper limit) contact SA-MAA type instantaneous flow rate indicator + with lower limit (upper limit) contact |
---|---|
Bore | 3/8B to 1B Flange type RC3/8 to RC1 Screw type |
Withstanding pressure | Standard product 1.0MPa |
Temperature | Standard product 80°C or less Special order item 300°C or less |
Accuracy | Each indication scale ±3% |
Capacity of contact | *50W: 0.5A,125VAC Self-holding proximity switch |
Material of main unit | FC250,CAC406,SS400,SUS304,SUS316,SUS316L etc. |
Material of main section | C3604B,SUS304,SUS316,SUS316L etc. |
Remark | *For places with frequent vibration, please use earthquake resistant type. |
Orifice flow meter
rate indicator to the corner tap orifice
realizes superior cost performance
and low-cost flow rate measurement
even for large bore.
Various types of flow rate indicators
are lined up to meet wide-ranging needs.
- Can select either digital indication or analog indication.
- For relay output, up to two contacts are available.
- Various output signals such as analog signal and HART communication function are available.
- If power supply cannot be ensured, the analog indicator type or the digital indicator is supported by a built-in battery type.
Type | ODF |
---|---|
Fluid to be measured | Liquid, gas (however, for corrosive fluid, please contact us) |
Bore | Wafer connection, flange connection 15A to 350A : JIS 5K/10K/16K/20K/30K FF/RF 1/2” to 14” : ANSI#150Lb #300Lb |
Maximum use pressure | Max. 2.0MPa (standard product) (for high pressure, please contact us) |
Temperature of fluid | -10~70°C(standard product) |
Accuracy | F.S. ±5% |
Installation location | can be installed outdoors <IP65> (however, please avoid direct sunlight) |
Material of main unit | SS400,SUS304,SU316,SUS316L etc. |
Material of plate | SUS304,SUS316,SUS316L etc. |
Remark | *If you are worried about pressure loss, please contact us. *Both horizontal piping and vertical piping can be used. *Drain for drainage can be installed. |
Example of use | *Cooling water line by purified water, industrial water, coolant liquid, etc. *Gas line of air, nitrogen, etc. *General process line |
FS type flow sight (transparent type sight glass)
Type | FS-I: without flapper FS-II: with flapper FS-B: ball contained FS-I-N: with nozzle FS-IV: for both purposes of forward and reverse FS-IV: for both purposes of forward and reverse FS-W: with wiper |
---|---|
Bore | 3/8B to 6B flange type (special order item to 12B) 3/8B to 2B screw type |
Withstanding pressure | 1.0MPa |
Temperature | 80°C or less (Standard product) |
Material | Main unit: FC250,FC450,CAC406,SS400,SUS304,SUS316 Main section: C2801P,SUS304,SUS316 |
Remark | For FS-II and FS-IV types, outline flow rate scales can be carved. |
FS-M / FS-O type flow sight (magnet servility type)
- With FS type, the index cannot be seen clearly due to oil or taint on window glass. However, with this flow sight type, the flow rate can be seen "clearly" because the index is attached on the outside of wetted surface.
Type | FS-M : Magnet servility type flow sight FS-O : Magnet servility type flow sight for small flow rate |
---|---|
Bore | *FS-M 3/8B to 6B Flange type (special order item to 12B) 3/8B to 2B Screw type *FS-O 3/8B to 1B Flange type (special order item to 12B) 3/8B to 1.1/2B Screw type |
Withstanding pressure | 1.0MPa |
Temperature | 80°C or less (Standard product) |
Material | Main unit: FC250、FC450、CAC406、SS400、SUS304、SUS316 Main section: C2801P、SUS304、SUS316 |
Remark | The model of this flow sight that complies with the Fire Service Act is FS-K type. |
FS-C / FS-N flow sight type with needle valve
Type | FS-C : As a cap is attached to the needle valve, other people cannot touch it easily once the oil quantity is set. FS-N : the needle valve is a 2.0MPa type for earthquake resistant and high-accuracy fine adjustment is possible |
---|---|
Bore | FS-C : 1/4B to 1.1/2B Screw type FS-N : 1/4B to 1B Screw type |
Withstanding pressure | 1.0MPa |
Temperature | 80°C or less (Standard product) |
Material | *FS-C Flow sight : Main unit FCD450, Main section C2801P Needle valve : Main unit CAC406, Main section C3604B *FS-N Flow sight : Main unit FCD450, Main section C2801P Needle valve : Main unit C3771B, Main section C3604B |
Remark | FS-K type comes with a protection cover made of steel complying with the Fire Service Act, and is without a window glass in order to prevent the damage of window glass. For small flow rate or when black oil is measured, please use FS-O type. |
FI type sight feed indicator
- The flow direction is side to bottom and a needle valve is attached to the inlet side for adjusting the amount of lubrication.
Type | FI-1 to FI-12 |
---|---|
Bore | FI-1 type : RC1/4×RC1/2 : Maximum flow rate 3L/min FI-2 type : RC3/8×RC1/2 : Maximum flow rate 3L/min FI-3 type : RC1/2×RC1/2 : Maximum flow rate 3L/min FI-4 type : RC1/4×RC3/4 : Maximum flow rate 5L/min FI-5 type : RC3/8×RC3/4 : Maximum flow rate 5L/min FI-6 type : RC1/2×RC3/4 : Maximum flow rate 5L/min FI-7 type : RC3/4×RC3/4 : Maximum flow rate 5L/min FI-8 type : RC1/4×RC1 : Maximum flow rate 5L/min FI-9 type : RC3/8×RC1 : Maximum flow rate 5L/min FI-10 type : RC1/2×RC1 : Maximum flow rate 5L/min FI-11 type : RC3/4×RC1 : Maximum flow rate 5L/min FI-12 type : RC1×RC1 : Maximum flow rate 10L/min |
Withstanding pressure | 1.0MPa |
Temperature | 80°C or less (Standard product) |
Material | Main unit : AC-8BT6, Main section : C3604B, Needle valve : SUS304 |
Remark | Product with a protection cover made of steel complying with the Fire Service Act is also manufactured for preventing the damage of window glass. |