KAWAKI MEASURING INSTRUMENT Co., LTD has manufactured
parts of shield machine of major heavy industry manufacturers,
hydraulic pressure-related parts of major machine manufacturers,
and parts for protecting voltage inverters of major heavy electric
manufacturers in addition to flow rate measurement gauge
(flow meter, flow switch, flow sight etc.) since the initiation
in April 1948. We are developing and manufacturing various types
of flow meters to meet a very wide range of market requests.
KY type flow switch / flow meter
- Suitable for unclear liquid because the indication part is separated using a mechanical seal
- Flow direction is not restricted
- Contact position is variable
Type | KY-M type instantaneous flow rate indicator KY-MA type instantaneous flow rate indicator + with lower limit (upper limit) contact |
---|---|
Bore | 3/8B to 5B Flange type RC3/8 to RC1.1/2 Screw type |
Withstanding pressure | Standard product 1.0MPa |
Temperature | Standard product 80°C or less |
Accuracy | Each indication scale ±5% |
Capacity of contact | *15A: 125,250 or 480VAC,0.5A: 125VDC,0.25A: 250VDC |
Application |
|
Material of main unit | FC250,CAC406,SUS304 |
Material of main unit | C3604B,SUS304 |
Remark | *For places with frequent vibration, please use earthquake resistant SF type. *If the use pressure is 1.0MPa or more, use SF type for high pressure. *The range of minimum scale is 0 to 30L/min (water) and 0 to 20L/min (oil). |
SF type flow switch / flow meter
- Suitable for high-temperature and high-pressure liquid of unclear liquid (oil etc.)
- The contact of flow switch is the internal variable type, however, if you change the contact frequently, the external variable type is also manufactured.
- For use outdoors and at places with bad environment, totally waterproof type (IEC, IP67) is also manufactured.
Type | SF-M type instantaneous flow rate indicator SF-MA type instantaneous flow rate indicator + with lower limit (upper limit) contact SF-MAA type instantaneous flow rate indicator + with lower limit (upper limit) contact |
---|---|
Bore | 3/8B to 12B Flange type RC3/8 to RC1.1/2 Screw type |
Withstanding pressure | Standard product 1.0MPa Special order item 3.0MPa and above |
Temperature | Standard product 80°C or less Special order item 300°C or less |
Accuracy | Each indication scale ±3% |
Capacity of contact | For the micro switch used for the contact, three types shown below are separately used depending on bore and flow rate. *15A: 125,250VAC、0.5A: 125VDC、0.25A: 250VDC *5A: 125,250VAC、0.5A: 125VDC、0.25A: 250VDC *10A: 125,250VAC |
Material of main unit | FC250,CAC406,SS400,SUS304,SUS316,SUS316L etc. |
Material of main section | C3604B,SUS304,SUS316,SUS316L etc. |
Remark | *For places with frequent vibration, please use earthquake resistant type. |
FY type flow switch / flow meter
- This flow meter / flow switch is the down-sized SF type and the features are same as those of SF type and SA type.
- The external variable type is also manufactured.
Type | FY-M type instantaneous flow rate indicator FY-M type instantaneous flow rate indicator |
---|---|
Bore | 3/8B to 12B Flange type RC3/8 to RC1.1/2 Screw type |
Withstanding pressure | Standard product 1.0MPa |
Temperature | Standard product 80°C or less |
Accuracy | Each indication scale ±3% |
Capacity of contact | *5A: 125,250VAC,0.5A: 125VDC,0.25A: 250VDC |
Material of main unit | FC250,CAC406,SUS304 |
Material of main section | C3604B,SUS304 |
Remark | *For places with frequent vibration, please use earthquake resistant SF type. *If the use pressure is 1.0MPa or more, use SF type for high pressure. *For use outdoors and at places with bad environment, totally waterproof type (IEC, IP67) is also manufactured. |
SA type flow switch / flow meter
- Suitable for comparatively small flow rate (equivalent to water 0 to 15L/min) of high-temperature and high-pressure fluid of unclear liquid (oil, etc.)
Self-holding proximity switch | SA-M type instantaneous flow rate indicator SA-MA type instantaneous flow rate indicator + with lower limit (upper limit) contact SA-MAA type instantaneous flow rate indicator + with lower limit (upper limit) contact |
---|---|
Bore | 3/8B to 1B Flange type RC3/8 to RC1 Screw type |
Withstanding pressure | Standard product 1.0MPa |
Temperature | Standard product 80°C or less Special order item 300°C or less |
Accuracy | Each indication scale ±3% |
Capacity of contact | *50W: 0.5A,125VAC Self-holding proximity switch |
Material of main unit | FC250,CAC406,SS400,SUS304,SUS316,SUS316L etc. |
Material of main section | C3604B,SUS304,SUS316,SUS316L etc. |
Remark | *For places with frequent vibration, please use earthquake resistant type. |
Orifice flow meter
A simple structure that attaches a flow
rate indicator to the corner tap orifice
realizes superior cost performance
and low-cost flow rate measurement
even for large bore.
Various types of flow rate indicators
are lined up to meet wide-ranging needs.
rate indicator to the corner tap orifice
realizes superior cost performance
and low-cost flow rate measurement
even for large bore.
Various types of flow rate indicators
are lined up to meet wide-ranging needs.
- Can select either digital indication or analog indication.
- For relay output, up to two contacts are available.
- Various output signals such as analog signal and HART communication function are available.
- If power supply cannot be ensured, the analog indicator type or the digital indicator is supported by a built-in battery type.
Type | ODF |
---|---|
Fluid to be measured | Liquid, gas (however, for corrosive fluid, please contact us) |
Bore | Wafer connection, flange connection 15A to 350A : JIS 5K/10K/16K/20K/30K FF/RF 1/2” to 14” : ANSI#150Lb #300Lb |
Maximum use pressure | Max. 2.0MPa (standard product) (for high pressure, please contact us) |
Temperature of fluid | -10~70°C(standard product) |
Accuracy | F.S. ±5% |
Installation location | can be installed outdoors <IP65> (however, please avoid direct sunlight) |
Material of main unit | SS400,SUS304,SU316,SUS316L etc. |
Material of plate | SUS304,SUS316,SUS316L etc. |
Remark | *If you are worried about pressure loss, please contact us. *Both horizontal piping and vertical piping can be used. *Drain for drainage can be installed. |
Example of use | *Cooling water line by purified water, industrial water, coolant liquid, etc. *Gas line of air, nitrogen, etc. *General process line |
FS type flow sight (transparent type sight glass)
Type | FS-I: without flapper FS-II: with flapper FS-B: ball contained FS-I-N: with nozzle FS-IV: for both purposes of forward and reverse FS-IV: for both purposes of forward and reverse FS-W: with wiper |
---|---|
Bore | 3/8B to 6B flange type (special order item to 12B) 3/8B to 2B screw type |
Withstanding pressure | 1.0MPa |
Temperature | 80°C or less (Standard product) |
Material | Main unit: FC250,FC450,CAC406,SS400,SUS304,SUS316 Main section: C2801P,SUS304,SUS316 |
Remark | For FS-II and FS-IV types, outline flow rate scales can be carved. |
FS-M / FS-O type flow sight (magnet servility type)
- With FS type, the index cannot be seen clearly due to oil or taint on window glass. However, with this flow sight type, the flow rate can be seen "clearly" because the index is attached on the outside of wetted surface.
Type | FS-M : Magnet servility type flow sight FS-O : Magnet servility type flow sight for small flow rate |
---|---|
Bore | *FS-M 3/8B to 6B Flange type (special order item to 12B) 3/8B to 2B Screw type *FS-O 3/8B to 1B Flange type (special order item to 12B) 3/8B to 1.1/2B Screw type |
Withstanding pressure | 1.0MPa |
Temperature | 80°C or less (Standard product) |
Material | Main unit: FC250、FC450、CAC406、SS400、SUS304、SUS316 Main section: C2801P、SUS304、SUS316 |
Remark | The model of this flow sight that complies with the Fire Service Act is FS-K type. |
FS-C / FS-N flow sight type with needle valve
Type | FS-C : As a cap is attached to the needle valve, other people cannot touch it easily once the oil quantity is set. FS-N : the needle valve is a 2.0MPa type for earthquake resistant and high-accuracy fine adjustment is possible |
---|---|
Bore | FS-C : 1/4B to 1.1/2B Screw type FS-N : 1/4B to 1B Screw type |
Withstanding pressure | 1.0MPa |
Temperature | 80°C or less (Standard product) |
Material | *FS-C Flow sight : Main unit FCD450, Main section C2801P Needle valve : Main unit CAC406, Main section C3604B *FS-N Flow sight : Main unit FCD450, Main section C2801P Needle valve : Main unit C3771B, Main section C3604B |
Remark | FS-K type comes with a protection cover made of steel complying with the Fire Service Act, and is without a window glass in order to prevent the damage of window glass. For small flow rate or when black oil is measured, please use FS-O type. |
FI type sight feed indicator
- The flow direction is side to bottom and a needle valve is attached to the inlet side for adjusting the amount of lubrication.
Type | FI-1 to FI-12 |
---|---|
Bore | FI-1 type : RC1/4×RC1/2 : Maximum flow rate 3L/min FI-2 type : RC3/8×RC1/2 : Maximum flow rate 3L/min FI-3 type : RC1/2×RC1/2 : Maximum flow rate 3L/min FI-4 type : RC1/4×RC3/4 : Maximum flow rate 5L/min FI-5 type : RC3/8×RC3/4 : Maximum flow rate 5L/min FI-6 type : RC1/2×RC3/4 : Maximum flow rate 5L/min FI-7 type : RC3/4×RC3/4 : Maximum flow rate 5L/min FI-8 type : RC1/4×RC1 : Maximum flow rate 5L/min FI-9 type : RC3/8×RC1 : Maximum flow rate 5L/min FI-10 type : RC1/2×RC1 : Maximum flow rate 5L/min FI-11 type : RC3/4×RC1 : Maximum flow rate 5L/min FI-12 type : RC1×RC1 : Maximum flow rate 10L/min |
Withstanding pressure | 1.0MPa |
Temperature | 80°C or less (Standard product) |
Material | Main unit : AC-8BT6, Main section : C3604B, Needle valve : SUS304 |
Remark | Product with a protection cover made of steel complying with the Fire Service Act is also manufactured for preventing the damage of window glass. |