EMP (E.M.P-Japan Ltd.) catalogs 12 models in this group. Compare the performance limits, electrical supply and physical interfaces for each model below.
Model selection
The lineup starts with the MV-05 for low-flow service and steps through the SV-10RRA and MV-10 variants. Compare the MV-70G with the MV-60G and MV-75HG when routing one or two gas branches. The ×2 flow notation preserves the catalog’s two-head figures.
The MV-600G and MV-603G both list a discharge endpoint above 40 kPa. They use different gas-contact materials and port diameters. For suction duty compare the signed vacuum values for these two units, the MV-610 and the MV-6005VP, then check the curve at the required gas flow.
Performance and electrical ratings
| Model | Max. flow (L/min) | Max. discharge (kPa) | Max. vacuum (kPa) | Rated voltage | Rated current (A) |
|---|---|---|---|---|---|
| MV-05 | 0.8 | 2.0 | -2.0 | 100 V AC | 0.05 |
| SV-10RRA | 2.0 | 6.6 | -6.6 | 100 V AC | 0.06 |
| MV-10 | 2.0 | 3.9 | -3.9 | 100 V AC | 0.05 |
| MV-10H | 4.0 | 10.6 | -10.6 | 100 V AC | 0.1 |
| MV-20B-C | 4.0 | 10.7 | -10.7 | 100 V AC | 0.15 |
| MV-60G | 3.5 × 2 | 14.6 | -10.6 | 100 V AC | 0.15 |
| MV-70G | 8.0 | 14.7 | -13.3 | 100 V AC | 0.13 |
| MV-75HG | 5.0 × 2 | 18.6 | -13.3 | 100 V AC | 0.25 |
| MV-600G | 6.0 | 42.6 | -39.9 | 100 V AC | 0.25 |
| MV-603G | 5.0 | 42.0 | -40.0 | 100 V AC | 0.25 |
| MV-610 | 5.0 × 2 | 13.3 | -13.3 | 115 V AC | 0.20 |
| MV-6005VP | 4.0 | 30.7 | -30.7 | 100 V AC | 0.13 |
The flow and pressure figures describe separate performance limits. Use the model curve to determine delivered flow at the actual pressure differential. An em dash indicates no catalog value.
Dimensions, connections and materials
| Model | H × W × L (mm) | Connection | Media-contact materials | Mass (kg) | Ambient (°C) | Insulation class |
|---|---|---|---|---|---|---|
| MV-05 | 70 × 36 × 51 | Ø6 | CR, PF | 0.20 | 0–40 | A |
| SV-10RRA | 76 × 36.5 × 56 | Ø6 | CR, PP | 0.30 | 0–40 | E |
| MV-10 | 91 × 40 × 58 | Ø6 | CR, PF | 0.35 | 0–40 | A |
| MV-10H | 91 × 40 × 58 | Ø6 | CR, PF | 0.35 | 0–40 | A |
| MV-20B-C | 106 × 47 × 65 | Ø6 | CR, PF | 0.60 | 0–40 | A |
| MV-60G | 47 × 87 × 128 | Ø6 | CR, PF | 0.90 | 0–40 | A |
| MV-70G | 46 × 71 × 117 | Ø6 | CR, PF | 0.70 | 0–40 | A |
| MV-75HG | 47 × 87 × 128 | Ø6 | CR, PF | 0.85 | 0–40 | A |
| MV-600G | 47 × 87 × 128 | Ø6 | CR, PF, Ni plating | 0.85 | 0–40 | A |
| MV-603G | 124 × 80 × 40 | Ø4 | CR, PF, PP | 0.35 | 0–40 | A |
| MV-610 | 47 × 87 × 128 | Ø6 | CR, PF, NiCr plating | 0.85 | 0–40 | A |
| MV-6005VP | 71 × 96 × 118 | Ø4 | CR, PP, PF, SR, Ni plating | 0.80 | 0–40 | A |
Dimensions follow the catalog comparison table and are listed as height × width × length. Check the mounting drawing for port position, mounting-hole spacing and service clearance. Confirm media compatibility using the materials listed for the exact model.