J-02F0.1G075 is a sample-gas filter reference used in continuous emissions monitoring system (CEMS) gas-conditioning assemblies. When sourcing this reference through JANAPO, confirm the exact configuration on the supplier’s drawing. JANAPO's published pages give detailed data for the related J-01P0.1G075 standard filter and J-S01P0.1G075 smart filter.
About JANAPO and Nanjing Assen Environmental Technology
JANAPO is a brand of Nanjing Assen Environmental Technology Co., Ltd. in Nanjing, China. The company's portfolio includes CEMS packages, flue-gas moisture and velocity instruments, sampling probes, sample coolers, heated lines, gas analyzers and peristaltic condensate pumps. It also supplies portable emissions testing and sample-conditioning equipment.
J-02F0.1G075 identification
Public system documentation identifies J-02F0.1G075 as an FT2 filter in a sample-gas conditioning system. Check the filter location on the cabinet drawing and confirm whether the replacement consists of the complete housing, the element, or a housing with fittings. Verify the port count, thread form, tube outside diameter, process-contact materials, filtration grade, pressure limit and any electrical connections from the unit-specific drawing. The model designation alone leaves these details to be confirmed.
JANAPO J-01 published configurations
| Catalogue model | Function | Published reference configuration |
|---|---|---|
| J-01P0.1G075 | Standard sample-gas filter | PP body, 0.1 µm fibre element, 75 mm element length |
| J-S01P0.1G075 | Smart filter with dew-point measurement | PP body, 0.1 µm fibre element, 75 mm element length, −40 to +60 °C dew-point range |
JANAPO lists a glass cover and PVDF fittings on those two configurations. The standard listings specify connections for 6 mm outside-diameter tubing and 1/4-inch NPT. The manufacturer lists alternative filtration grades and media in its filter family. The smart model adds a dew-point alarm output, so the sensor and electrical connection may affect the layout of a replacement.
Matching a replacement to an analyzer cabinet
Identify the sampling point relative to the cooler, pump and analyzer. Confirm the allowed flow restriction, condensate connection, alarm wiring if present and maximum operating conditions. Use the existing assembly photo and piping diagram to identify threads and the gas flow path. For an element-only replacement, confirm length, material, rating and seals with the manufacturer.