Product description
FS-I-3P combines visual return-line monitoring with a mounting seat for a thermometer thermowell. It is intended for oil and water return piping, waste-oil lines and drain lines where condition and temperature monitoring are needed in a compact assembly.
Flow path and temperature monitoring
The specified mounting arrangement is side-entry to bottom-exit. State the required thermowell length with the order so that the temperature element and the sight-glass assembly fit the piping. The standard maximum fluid temperature is 120 °C and the standard maximum pressure is 1.0 MPa.
Viewing protection and materials
Outdoor use is listed. A protective cover can be fitted over the viewing glass to reduce glass damage and fragment dispersion. Select the body grade, flange dimensions and required pressure loss for the fluid and duty. Higher-pressure construction requires a specified design.
Selection and ordering
Specify the fluid, operating pressure and temperature, required measuring range, flow direction, pipe size and connection standard. Match body, internal parts and seals to the medium. For a switch version, state the alarm setpoint and the control-circuit voltage and load so that the contact arrangement can be selected.
Specifications
| Item | Catalog specification |
|---|---|
| Model | FS-I-3P |
| Fluid | Liquid |
| JIS connection | 40A–200A; 5K / 10K, FF / RF |
| ANSI / JPI connection | 1 1/2–8 in; Class 150 |
| Standard maximum pressure | 1.0 MPa |
| Standard maximum temperature | 120 °C |
| Mounting flow path | Side → bottom |
| Thermowell | Length to be specified |
Product images