MTL MC-200-7220A and MC-200-7220D Compact Servo Drivers
The MC-200-7220 family provides compact position, velocity and current control for compatible servo motor systems. The A configuration supports digital/analog I/O, while the D configuration supports SPI communication. USB is used for parameter setup, monitoring and command functions.

Technical specifications
| Parameter | Specification |
|---|---|
| Nominal supply | 48 VDC |
| Supply range | 20 VDC −5% to 72 VDC +5% |
| Continuous output | 3.5 Arms |
| Peak output, less than one second | 20 Arms |
| Drive method | Sinusoidal PWM, 50 kHz |
| Control modes | Position, velocity, current |
| Protection | Overcurrent, overload, overvoltage, undervoltage, overheating, encoder error; fuse protection |
| USB | USB 2.0 mini-B; setup, monitoring and command control |
| Pulse command | Line-driver input up to 2.5 MHz at ×1; CW/CCW, pulse/direction or two-phase pulse |
| Analog command | ±5 V relative to 0 V, 12 bit |
| Auxiliary inputs | Servo on, alarm reset, current/speed control, homing, emergency stop and general inputs |
| Outputs | Positioning complete, alarm and analog monitor of current/speed/position deviation |
| Encoder output | Incremental: ABZ line driver; absolute: RS-422 ASCII or binary |
| External command | I/O, SPI or USB, configuration-dependent |
| Dimensions | 132 × 67.2 × 25 mm |
| Mass | 160 g |
Configuration and selection
Match the A or D command interface to the intended controller. The continuous current and sub-second peak current are different ratings; use the applicable duty and motor pairing. Encoder outputs depend on whether incremental or absolute feedback is installed.

Integration and commissioning
Match the drive supply, motor current, feedback type and command interface before connecting the system. Peak output is specified for less than one second and should not be used as a continuous-current capability. Confirm the motor parameters, current limits and thermal duty for the installed motor.
Verify direction, encoder interpretation, command scaling and alarm behavior at low demand before enabling normal motion. Check connector pin assignments and cable arrangements for the actual variant. Replacement of a drive requires verification of these electrical and control details as well as the physical mounting envelope.
Specification interpretation
Encoder position divisions and positioning repeatability are different quantities. Incremental counts quoted after ×4 decoding should be compared on the same basis, while an absolute bit count describes a separate feedback format. Evaluate the completed axis, including its load, controller and mounting, before adopting a performance figure as a machine-level result.