MTL MDH(12)-4006, MDH(12)-4012, MDH(12)-4018 12 mm Hollow-Shaft Direct Drive Motors
The MDH(12)-40 enlarges the hollow diameter of the 40 mm motor platform to 12 mm. This creates space for cable, laser or other through-axis arrangements in compact automation equipment.

Technical specifications
| Parameter | Specification |
|---|---|
| Body diameter | φ40mm |
| Body length | 31.5/37.5/43.5mm |
| Maximum torque | 0.33/0.70/1.0N·m |
| Maximum speed | 450rpm |
| Encoder resolution options | 1,296,000P/R(after ×4 decoding) |
| Hollow diameter | φ12mm |
| Parameter | Unit | MDH(12)-4006 | MDH(12)-4012 | MDH(12)-4018 |
|---|---|---|---|---|
| Supply voltage at driver input | DCV | 24/48 | 24/48 | 24/48 |
| Maximum speed | rpm | 450 | 450 | 450 |
| Instantaneous maximum torque | Nm | 0.33 | 0.7 | 1 |
| Continuous stall torque | Nm | 0.12 | 0.2 | 0.28 |
| Continuous rated torque | Nm | 0.1 | 0.16 | 0.23 |
| Instantaneous maximum power | W | 14 | 27 | 40 |
| Instantaneous maximum power rate | kW/s | 39 | 120 | 98 |
| Instantaneous maximum current | Arms | 6.3 | 7.5 | 10 |
| Continuous rated current | Arms | 1.6 | 1.7 | 2.3 |
| Equivalent back-EMF constant | V/krpm | 6.1 | 10 | 11 |
| Equivalent torque constant at 25 °C | Nm/Arms | 0.058 | 0.096 | 0.1 |
| Line-to-line armature resistance at 25 °C | Ω | 2.6 | 2.5 | 1.7 |
| Line-to-line armature inductance | mH | 2.6 | 3 | 2 |
| Rotor poles | P | 16 | 16 | 16 |
| Maximum encoder resolution | P/R | Incremental:1,296,000 | Incremental:1,296,000 | Incremental:1,296,000 |
| Rotor inertia | g·cm^2 | 49.8 | 64.6 | 79.4 |
| Permissible radial load | N | 140 | 140 | 140 |
| Permissible axial load | N | 70 | 70 | 70 |
| Permissible moment | Nm | 4.8 | 5.5 | 6.3 |
| Load reference distance La | mm | 35.2 | 41.2 | 47.1 |
| Mass | kg | 0.21 | 0.26 | 0.3 |
| Listed compatible driver families | MC-200-7220 / MC-200C-6018 | MC-200-7220 / MC-200C-6018 | MC-200-7220 / MC-200C-6018 | |
| Reference aluminum heat sink (mm) | 150×150×8 aluminum | 150×150×8 aluminum | 150×150×8 aluminum |
Configuration and selection
The page contains an inconsistent rated-speed entry greater than its stated maximum; that rated-speed row is omitted. A separate note limits a specified 648,000-pulse configuration to 277 rpm because of response frequency. Confirm speed against the selected encoder and drive.

Ratings and thermal conditions
Instantaneous maximum torque, continuous stall torque and continuous rated torque describe different operating conditions. Use continuous ratings for sustained operation and check the complete acceleration, deceleration and dwell cycle for peak demand. Where the table lists 24/48 V driver input, the manufacturer states that instantaneous maximum torque changes at 24 V. Confirm the required torque at the actual supply voltage.
Continuous rated current is measured at an ambient temperature of 40 °C with the stated reference heat sink attached. The final machine mounting and cooling arrangement must therefore be assessed before applying the same continuous current. Encoder resolution, drive response and the selected feedback configuration can also constrain usable speed. Confirm the motor and driver as a matched system.
Installation and control integration
Check body diameter, axial length, hollow passage and mounting drawing against the complete load arrangement. Radial load, axial load and permissible moment are separate constraints. Route through-axis cables or tubes so they do not apply unverified loads to the shaft or interfere with the moving assembly.
Select the servo driver, motor cable and encoder cable for the exact motor and feedback configuration. The motor pages list MC-200-7220 and older MC-200C-6018 drive families, but the latter is marked as production suspended in its dedicated listing. Confirm current drive availability and the required command interface; do not infer an AC motor connection from a collaboration amplifier option.
Specification interpretation
Encoder position divisions and positioning repeatability are different quantities. Incremental counts quoted after ×4 decoding should be compared on the same basis, while an absolute bit count describes a separate feedback format. Evaluate the completed axis, including its load, controller and mounting, before adopting a performance figure as a machine-level result.