EMP (E.M.P-Japan Ltd.) catalogs 6 models in this group. Compare the performance limits, electrical supply and physical interfaces for each model below.
Model selection
The compact CM-15W variants share the same 0.1 L/min flow and 30 kPa discharge endpoints. The supply options span 3 to 24 V DC, with current specified separately by model. Their EPDM and PBT liquid-contact components connect through a Ø5.5 port.
Among the 24 V DC units, the BL-200-FFS has a 500 kPa discharge endpoint and uses FKM and modified PPE. The CM-05W-24 lists 0.5 L/min maximum flow and a 150 kPa discharge endpoint, with EPDM and POM in the liquid path. These figures help narrow a shortlist by pressure, throughput and chemical compatibility.
Performance and electrical ratings
| Model | Max. flow (L/min) | Max. discharge (kPa) | Max. vacuum (kPa) | Rated voltage | Rated current (A) |
|---|---|---|---|---|---|
| CM-15W-24 | 0.1 | 30.0 | -20.0 | 24 V DC | 0.12 |
| CM-15W-12 | 0.1 | 30.0 | -20.0 | 12 V DC | 0.2 |
| CM-15W-6 | 0.1 | 30.0 | -20.0 | 6 V DC | 0.4 |
| CM-15W-3 | 0.1 | 30.0 | -20.0 | 3 V DC | 0.8 |
| BL-200-FFS | 0.2 | 500.0 | -65.0 | 24 V DC | 0.32 |
| CM-05W-24 | 0.5 | 150.0 | -50.0 | 24 V DC | 0.25 |
The flow and pressure figures describe separate performance limits. Use the model curve to determine delivered flow at the actual pressure differential. An em dash indicates no catalog value.
Dimensions, connections and materials
| Model | H × W × L (mm) | Connection | Media-contact materials | Mass (kg) | Ambient (°C) | Insulation class |
|---|---|---|---|---|---|---|
| CM-15W-24 | 23.5 × 31 × 74 | Ø5.5 | EPDM, PBT | 0.06 | 0–40 | E |
| CM-15W-12 | 23.5 × 31 × 74 | Ø5.5 | EPDM, PBT | 0.06 | 0–40 | E |
| CM-15W-6 | 23.5 × 31 × 74 | Ø5.5 | EPDM, PBT | 0.06 | 0–40 | E |
| CM-15W-3 | 23.5 × 31 × 74 | Ø5.5 | EPDM, PBT | 0.06 | 0–40 | E |
| BL-200-FFS | 62 × 44 × 66 | Rc1/8 | FKM, m-PPE | 0.30 | 0–40 | E |
| CM-05W-24 | 68.3 × 114.5 × 69 | Ø6 | EPDM, POM | 0.35 | 0–40 | A |
Dimensions follow the catalog comparison table and are listed as height × width × length. Check the mounting drawing for port position, mounting-hole spacing and service clearance. Confirm media compatibility using the materials listed for the exact model.
EMP product photos