MR-48 and MR-50 are straight-tube rollers with Ø48.6 and Ø50 mm bodies. Their listed standard three-phase configurations use voltage code 6, so retain the exact tube and motor fields when replacing an installed roller.
Selection and fit
Compare the roller diameter with the conveyor support plane. The same nominal speed code gives different load speeds and surface forces at the two diameters. Use the catalog width table for the selected brake, sealed or driven-idler arrangement. Check the required face width, the frame clearance and the minimum width for the selected speed, gearbox and options before completing the order code.
Reading the reference table
These are catalog reference values for the specified standard three-phase 200 V configuration. The nominal speed code identifies the gearing. Actual surface speed changes with load and frequency. Compare starting force and rated force separately.
Catalog motor configurations
| Diameter (mm) | Order-code family | Motor code | Catalog supply / variant |
|---|---|---|---|
| 48.6 | MR-A3-48 | 6 | 200 V class, three-phase |
| 50 | MR-A3-50 | 6 | 200 V class, three-phase |
Standard three-phase reference point
| Size | Nominal speed code | Rated speed 50 / 60 Hz (m/min) | Rated tangential force 50 / 60 Hz (N) | Starting tangential force 50 / 60 Hz (N) | Rated torque 50 / 60 Hz (N·cm) |
|---|---|---|---|---|---|
| MR-48 | 30 | 28.0 / 33.9 | 13.9 / 12.3 | 43.9 / 36.8 | 33.8 / 30.0 |
| MR-50 | 30 | 28.8 / 34.9 | 13.5 / 12.0 | 42.7 / 35.8 | 32.9 / 29.2 |