The Ø57 mm straight-tube family includes models for single-phase 100 V and 200 V classes, three-phase 200 V and 400 V classes, and a high-output three-phase 200 V option.
Selection and fit
The manufacturer identifies impedance protection for certain standard voltage configurations, with exclusions by voltage and frequency. Treat the high-output and single-phase 200 V configurations as separate electrical selections. A stopped package can still slip against a turning roller, which may mark the tube or product. Check the required face width, the frame clearance and the minimum width for the selected speed, gearbox and options before completing the order code.
Reading the reference table
These are catalog reference values for the specified standard three-phase 200 V configuration. The nominal speed code identifies the gearing. Actual surface speed changes with load and frequency. Compare starting force and rated force separately.
Catalog motor configurations
| Diameter (mm) | Order-code family | Motor code | Catalog supply / variant |
|---|---|---|---|
| 57 | MR-A1-57 | B | 100 V class, single-phase |
| 57 | MR-A1-57 | Q | 200 V class, single-phase |
| 57 | MR-A3-57 | A | 200 V class, three-phase |
| 57 | MR-A3-57 | G | 400 V class, three-phase |
| 57 | MR-A3-57 | H | 200 V class, three-phase, high output |
Standard three-phase reference point
| Size | Nominal speed code | Rated speed 50 / 60 Hz (m/min) | Rated tangential force 50 / 60 Hz (N) | Starting tangential force 50 / 60 Hz (N) | Rated torque 50 / 60 Hz (N·cm) |
|---|---|---|---|---|---|
| MR-57 | 30 | 25.3 / 30.1 | 19.8 / 16.5 | 36.9 / 33.3 | 56.4 / 47.0 |
Product images